MINIFLUX Sanitary container pump

For hygiene applications

Branch: IndustryBranch: Surface technologyBranch: CosmeticsBranch: PharmacyBranch: PetrochemistryBranch: AgricultureBranch: Water treatmentBranch: Paints and lacquersBranch: ChemistryBranch: Food

The horizontally installed, compact MINIFLUX Sanitary IBC container pump was designed for emptying IBCs and other containers with a bottom outlet. It is intended as an alternative to vertical drum pumps for cases where containers can only be accessed from above with great difficulty if at all. It is also ideal if the medium’s natural outlet via the outlet tap does not provide sufficient pumping pressure for filling at speed or transferring to a container at a higher level, for example. The MINIFLUX is driven by a commutator motor, compressed air motor or brushless motor.

The MINIFLUX Sanitary is also designed for use in the hygiene sector. It is FDA-compliant and can be dismantled in a matter of seconds without any tools.

  • Application areas: FDA  

Technical data:

  • Flow rate: max. 240 l/min1
  • Delivery head: max. 13 mwc2
  • Viscosity: min. 1 mPas - max. 1000 mPas2
  • Outer tube diameter:
  • Immersion length: Für den horizontalen Einsatz am IBC
  • Materials outer tube: Stainless steel
  • Media / Fluids: Egg mixture, Thin media
  • Seal: FKM or EPDM
  • Container: 1000 l IBC, Container with floor drain
  • 1 The maximum delivery rate is a test bench value, measured with water at 20 ° C at the pressure port of the pump, without accessories (hose, nozzle, flow meter). The practically achievable delivery rate is lower. It depends on the individual application, the fluid properties and the pump configuration. Please refer to technical data sheets / performance diagrams.
  • 2 dependent on pump model, motor and medium

Product attributes

  • To pump from IBCs, bag-in-box IBCs and other containers with an outlet connection at their base
  • Dry-installed pump
  • Little contact with the medium
  • Can be combined with commutator motor, brushless motor or compressed air motor
  • IBCs can be emptied to a residual volume of less than 1 % (depending on the angle of inclination)
  • Low total weight

Benefits

  • Suited to running dry under certain conditions
  • Particularly well suited to hygiene applications
  • FDA CFR 21 compliant
  • Features lip seal (not a mechanical seal)
  • Has minimal dead space
  • Can be dismantled without any tools, easy to clean
  • No greased seals – no risk of greases getting into the medium